2 March 2012 Anode thermal analysis of high power microfocus CNT x-ray tubes for in vivo small animal imaging
Author Affiliations +
Abstract
Carbon nanotube (CNT) micro-focus x-ray tubes have been demonstrated as a novel technology for in-vivo small animal imaging. It enables simultaneous respiratory and cardiac gated prospective CT imaging of free breathing animals with high temporal resolution. Operating the micro-focus CNT x-ray source at high power is required to achieve high temporal resolution. The thermal loading of the anode focal spot is a limiting factor in determining the maximum power of an x-ray tube. In this paper, we developed a reliable simulation model to quantitatively analyze the anode heat load of the CNT x-ray source operating in both DC and pulse modes. The anode temperature distribution is simulated using finite element analysis. The model is validated by comparing simulation results for the micro-focus x- ray tube with reported experimental results. We investigated the relationship between the maximum power and the effective focal spot size for CNT micro-CT system running in both DC and pulse modes. Our results show that when operating in pulse mode, the maximum power of the CNT x-ray source can be significantly higher than when operating in DC mode. In DC mode, we found that the maximum power scales non-linearly with the effective focal spot size as P(in W) = (0.25/ sin θ+1.6)f0.73 s (in μm), where 1/sin θ is the projection factor for a given anode angle θ. However, in pulse mode the maximum power linearly increases with the effective focal spot size asP(in W) = (0.20/ sin θ+0.35)fs(in μm), and is significantly higher than that in the DC mode. This implies that it is feasible to improve the micro-CT temporal resolution further without sacrificing the image quality. The simulation method developed here also enables us to analyze the thermal loading of the other CNT x-ray sources for other applications, such as the stationary digital breast tomosynthesis scanner and the CNT microbeam radiation therapy system.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jing Shan, Otto Zhou, and Jianping Lu "Anode thermal analysis of high power microfocus CNT x-ray tubes for in vivo small animal imaging", Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 83130O (2 March 2012); https://doi.org/10.1117/12.911521
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Electron beams

X-ray sources

X-ray imaging

Temporal resolution

In vivo imaging

Imaging systems

RELATED CONTENT

THERMAL analysis of high power x ray target scaling...
Proceedings of SPIE (August 26 2015)
Seventh-generation CT
Proceedings of SPIE (March 31 2016)
Image-based characterization of microfocus x-ray target failure
Proceedings of SPIE (September 16 2016)
4D micro-CT-based perfusion imaging in small animals
Proceedings of SPIE (March 13 2009)
High intensity electron beam for liquid metal jet anode hard...
Proceedings of SPIE (September 10 2005)

Back to Top