Physics of Medical Imaging

Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers

[+] Author Affiliations
Sun Il Kwon, Eric Berg, Simon R. Cherry, Emilie Roncali

University of California Davis, Department of Biomedical Engineering, Davis, California 95616, United States

Alessandro Ferri, Alberto Gola, Claudio Piemonte

Fondazione Bruno Kessler, via Sommarive 18, Trento, Italy

J. Med. Imag. 3(4), 043501 (Nov 23, 2016). doi:10.1117/1.JMI.3.4.043501
History: Received August 8, 2016; Accepted October 28, 2016
Text Size: A A A

Abstract.  Current research in the field of positron emission tomography (PET) focuses on improving the sensitivity of the scanner with thicker detectors, extended axial field-of-view, and time-of-flight (TOF) capability. These create the need for depth-of-interaction (DOI) encoding to correct parallax errors. We have proposed a method to encode DOI using phosphor-coated crystals. Our initial work using photomultiplier tubes (PMTs) demonstrated the possibilities of the proposed method, however, a major limitation of PMTs for this application is poor quantum efficiency in yellow light, corresponding to the wavelengths of the converted light by the phosphor coating. In contrast, the red-green-blue-high-density (RGB-HD) silicon photomultipliers (SiPMs) have a high photon detection efficiency across the visible spectrum. Excellent coincidence resolving time (CRT; <210  ps) was obtained by coupling RGB-HD SiPMs and 3×3×20  mm3 lutetium fine silicate crystals coated on a third of one of their lateral sides. Events were classified in three DOI bins (6.7-mm width) with an average sensitivity of 83.1%. A CRT of 200  ps combined with robust DOI encoding is a marked improvement in the phosphor-coated approach that we pioneered. For the first time, we read out these crystals with SiPMs and clearly demonstrated the potential of the RGB-HD SiPMs for this TOF-DOI PET detector.

Figures in this Article
© 2016 Society of Photo-Optical Instrumentation Engineers

Citation

Sun Il Kwon ; Alessandro Ferri ; Alberto Gola ; Eric Berg ; Claudio Piemonte, et al.
"Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers", J. Med. Imag. 3(4), 043501 (Nov 23, 2016). ; http://dx.doi.org/10.1117/1.JMI.3.4.043501


Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


 

  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.